Optimised climate control

Turf Cooling

  • Increase air circulation
  • Prevent heat stress
  • Decrease risk of turfgrass diseases

Improve micro climate

Often in sport venues, there is a lack of air circulation. This results in unfavourable conditions for growing turfgrass, amongst which a higher disease pressure and risk of diseases. This turf fan can be extended with a cooling option, to lower temperatures during the high temperatures in order to prevent plant stress and grass diseases. With the turf fan you control the air circulation and cooling seperately or combined to create perfect pitch circumstances.

The SGL TC50 blows a spray of water across the pitch of the BBVA Stadium, home of C.F. Monterrey.

Adiabatic cooling

When using the cooling on the turf fan, it cools the surface through the principle of adiabatic cooling, also known as evaporative cooling. It is a method of cooling air through the evaporation of water. The Turf Cooling system sprays a consistent stream of mist which is being carried 50 meters across the surface by the fan. The mist abstract the heat energy from the air above the surface, making the mist evaporate before it touches the grass. This results in a cool and dry playing surface. This cooling process can lower the temperatures with an average of 7-8 degrees Celsius, depending on the outside temperatures and natural wind.

The SGL TC50 cooling down the pitch of Bucharest National Stadium.

Data driven pitch management

TurfBase is the user-friendly tool for grounds managers to log, monitor and analyse data, to make and justify decisions regarding pitch quality and efficient use of resources. In addition, TurfBase optimises operation and efficiency of all SGL products, adding value to the hardware.

Data from TurfBase will help you use your TC50 to its full capacity. The most important module to support the TC50 is the Airflow Advice, which offers a 7-day forecast to guide the optimal use of turf fans and cooling systems.

Airflow Advice is only included in the Expert Plan, but you can also add this module to other plans via our Flex option. Let the data help you take your pitch management to the next level!

Learn more about TurfBase
Agronomist Remco van Adrichem and Head Groundsman Simeon Liljenberg inspecting the Friends Arena pitch/

TurfAssist

Keep your pitch performing at its best all year round with TurfAssist. From a free discovery phase to a full subscription, we deliver continuous data insights, expert agronomy advice, and tailored coaching. Whether it’s tackling seasonal challenges or fine-tuning daily maintenance, TurfAssist equips you with the knowledge and support to achieve a top-quality playing surface.

When it comes to tackling and controlling turf diseases, expert advice is essential. By managing the microclimate, you can reduce plant stress and prevent disease outbreaks, ensuring that your pitch remains healthy and safe. We will show you how to use your grass disease management products and the Disease Forecast module in TurfBase to proactively prevent outbreaks and minimise stress in a sustainable way, keeping your playing field healthy, resilient and safe.

Learn more about TurfAssist
Stefan Staijen, SGL Service Engineer, works on the LED50.

Service

Keep your Grass disease management products performing at its peak with Service. Our Service experts provide annual inspections, preventative maintenance, repairs and the latest software updates to ensure reliable performance, minimise unexpected costs, and maximise the lifespan and efficiency of your system. Our four packages: Parts Coverage, Essential, Premium, and Custom, each offer a different level of support and can be upgraded anytime to match your operational requirements.

More on Service
The SGL TC50 on the pitch of the Opus Arena in Osijek, Croatia.

Technical specifications

Machine dimensions L 1.55 m x W 1.6 m x H 2.35 m
Machine dimensions incl. wheel set L 2.35 m x W 2.08 m x H 2.38 m
Weight 615 kg
Horizontal rotation 270 degrees
Throwing distance 50 meters
Water pressure and consumption 20 Bar, approx. 540 L/h
kW consumption fan / boosterpump / oscillator 7.5 kW / 3 kW / 0.09 kW
Water connection 1’’ BSP male
Electrical plug 63 A (3P+N+E) 400V